Refrigerant Type Air Dryer
Technical Data
|
Filter Type (Grade)
|
SB
|
PF
|
UF
|
AC
|
NX
|
|
Maximum Operating Pressure - bar.g. (0002 - 1800)
|
16
|
16
|
16
|
16
|
16
|
|
Maximum Recommended Operating Temp. °C
|
65
|
65
|
65
|
35
|
180
|
|
Minimum Recommended Operating Temp. °C
|
1.5
|
1.5
|
1.5
|
1.5
|
1.5
|
|
Initial Clean Differential Pressure at nominal flow: P bar
|
0.08
|
0.1
|
0.12
|
0.08
|
0.14
|
|
Initial "Wet" Differential Pressure: P bar
|
0.1
|
0.14
|
0.2
|
0.2
|
0.3
|
|
Maximum recommended Differential Pressure for Element Change: P bar
|
0.7-1
|
0.7-1
|
0.7-1
|
1000
hrs
|
0.7-1
|
|
Efficiency: 21°C, 1 bar, abs at an inlet concentration of
3mg/m3 SB: 100% related to pore size PF: 0.5 mg/m3 PF + UF 0.01 mg/m3 (0.01PPM) 99.9999% PF + UF + AC -< 0.003 mg/m3 (< 0.003 PPM)
|
|
|
|
|
|
Operation Charcteristics
MS Moisture separator. For the
removal of 99% bulk oil / water from the compressed air system.
Filter Type SB: Pre-Filtration
Sintered bronze filter element for the
removal of pipe scales, bulk liquid, solid particles, dust down to
down 5 micron. Ideal as pre filter before line filter (Filter element
regenerable) available in 25, 10, 5 microns.
Filter Type PF: High Efficiency Fine
Filter
For the removal of particles down to 1
micron including coalesced liquid water and oil, dust, providing a
maximum remaining oil aerosol content of 0.5mg/m3 at 21°C
Filter Type UF: High Efficiency Oil
Removal Filtration
For the removal of particles down to
0.01 micron including water and oil aerosols, dust, proving a maximum
remaining oil aerosol content of 0.01mg/m3 (0.01 ppm) at 21°C
efficiency - 99.9999% (install in series with filter type PF). (Borosilicate glass micro fibres - media which actively repel oil
and water to reduce pressure drop and running cost to an absolute
minimum)
Filter Type AC: Activated Carbon
Filtration.
For the removal of vapour and
hydrocarbon odours giving a maximum remaining oil content of
<0.003mg/m3 (<0.003 ppm) (w) (excluding methane) at 21°C
(install in series with filter type PF+UF).
Note: It is essential to change the filter
elements every year or earlier if the clogging indicator (D.P Gauge)
changes to red.
Filter elements available
- Designed to customer specifications.
- To suit other manufactures housings.
|